工频过电压

  • 网络power frequency overvoltage;temporary overvoltage;r.m.s
工频过电压工频过电压
  1. 本文对阳城&江苏500kV输电系统的工频过电压、潜供电流以及三相合闸、单相重合闸过电压利用EMTP进行了计算。分析表明,该系统工频过电压符合有关规定;

    The computation of power frequency overvoltage , secondary arc current , 3 phase closing overvoltage and single phase reclosing overvoltage in Yangcheng Jiangsu 500 kV power transmission system by EMTP is presented in this paper .

  2. 讨论了空载线路在电容效应下产生的工频过电压,并对并联电抗器抑制工频过电压的作用进行了理论分析。

    The power frequency overvoltage of unloaded line because of the capacity effect is studied , and the effect of eliminating power frequency overvoltage using shunt reactors is analyzed .

  3. SVC对限制超高压输电系统工频过电压的影响

    Effect of SVC on restricting the temporary overvoltage of EHV transmission system

  4. 500kV同塔四回线路工频过电压研究

    Power frequency over-voltage of 500 kV four-circuit lines on the same power

  5. 750kV输电系统的工频过电压计算

    Calculation on Working Frequency Over-voltage for 750 kV Transmission System

  6. 1000kV长距离交流输电线路工频过电压仿真研究

    Study on simulation of fundamental frequency overvoltages for UHV AC transmission lines

  7. 本文从影响配电网的三个因素:工频过电压、谐振过电压以及电压闪变入手,分析了现代配电网的运行状态。并提出用静止无功补偿器(SVC)抑制电压闪变的控制策略。

    So this paper analyzed the running state by taking account of power over-voltage , resonance over-voltage and voltage flash , and propounded the strategy that voltage flash were controlled by using Static var compensator ( SVC ) .

  8. 笔者分析计算了SVC对提高系统输送能力和限制工频过电压的影响,讨论了超高压输电系统中部分应用SVC可以保证各种运行方式下的运行可靠性和经济性。

    The effect of SVC on improving transmission capability and limiting temporary overvoltage is analyzed by calculation in this paper . An idea of employing SVC partly in the EHV system is discussed to ensure reliability and economy under different operation modes .

  9. 为了研究工频过电压与系统运行方式的关系,应用二端口理论,具体分析了它们的联系,并对一个真实的500kV输电系统,计算了不同运行方式下的工频过电压。

    In order to investigate the relationship between power frequency over-voltage and operation mode of electric power system , theoretical analysis is made in this paper . Then , aiming at a practical 500 kV power system , a series of calculations are performed with various operation modes .

  10. 计算了各种采用光缆复合架空地线情况下线路的工频过电压。

    The power-frequency overvoltage is calculated in various conditions with OPGW .

  11. 良导体地线限制超高压输电系统工频过电压的作用

    Effect of ACSR on Suppressing Power Frequency Overvoltage of EHV Transmission System

  12. 系统的运行方式与工频过电压

    Operation mode of electric power system and power frequency over-voltage

  13. 基于PSCAD/EMTDC软件的空载线路工频过电压分析

    Analysis of power frequency over-voltage for unloaded lines by using PSCAD / EMTDC

  14. 计及非线性元件特性的工频过电压计算方法

    A method of temporary overvoltage calculation with the characteristics of non-linear elements taken into account

  15. 氧化锌压敏电阻器工频过电压耐受性能与限制电压关系的研究

    Research for the Relationship between Power Frequency Over-voltage Withstanding Performance and Clamping Voltage of ZnO Varistor

  16. 确定超高压远距离输变电系统绝缘水平时,工频过电压起着重要的作用。

    Temporary overvoltage is an important factor for the determination of insulation level in a long distance EHV or UHV transmission system .

  17. 给出了系统参数选择的依据,研究了工频过电压在不同条件下的限制方式。

    It also gives out the criteria for selection of system parameters and studies the limit mode of over-voltage of working frequency under different conditions .

  18. 对有补偿和无补偿的超高压输电线路在工频过电压、操作过电压方面进行了对比性研究。

    Comparative analysis of series compensated and non series compensated EHV transmission line in power frequency over-voltage and switching over-voltage is destriked in this paper .

  19. 静止无功补偿器电容元件上工频过电压分析

    Mathematical Analysis on the Behavior of the Capacitors in a Given Static Volt-Ampere Reactive Compensator ( SVARC ) When Over-Voltage at Working Frequency is Applied to Them

  20. 通过比较不同型号良导体地线的波阻抗,分析了零序阻抗对不对称接地工频过电压的影响。

    The influence of zero-sequence impedance on power-frequency overvoltage of asymmetric eathing fault is researched though comparing surge impedance of different types of ACSR as ground-return wires .

  21. 研究和计算都表明,工频过电压幅值很大程度上决定于系统的运行方式,若系统运行方式不同,过电压可能会有很大差异。

    The results show that power frequency over-voltage does have relationships with the operation mode to a great extent , and different operation modes may cause distinct values of over-voltage .

  22. 短距离特高压输电线路的过电压问题已有研究,而当传输距离进一步增加时,工频过电压情况更为严重,抑制方法更为复杂。

    The overvoltage of short-distance transmission line has already been studied . With the transmission distance increasing , the fundamental frequency overvoltage becomes more severely and the retraining methods more complicated .

  23. 大气过电压保护目前已形成了多种方式和多级结构,本文讨论多种保护方案的具体设计和实现,重点研究工频过电压的防护问题。

    Various and multi - stage atmospheric overvoltage protection solutions are available , and the specific design and implementation of multiple protection solutions are discussed , especially the issue of industrial frequency overvoltage protection .

  24. 算法模块包括了黑启动路径方案的初始生成、自励磁的校验、工频过电压、操作过电压、电压和频率的稳定性等计算,以及路径评估和排序模块。

    Algorithm module includes an initial program of black start path generation , self-excitation of the parity , power frequency overvoltage , operation overvoltage , voltage and frequency stability calculations , and the path evaluation and sorting .

  25. 可控高压并联电抗器(以下简称可控高抗)对于限制工频过电压和操作过电压、抑制潜供电流、进行线路容性无功功率补偿和电压控制,增强电网稳定性和提高输送能力具有重要意义。

    The Controlled Parallel Reactor is important for restricting the frequency overvoltage , the operating overvoltage and the secondary arc current . It is also important for improving the voltage stability and the transmission capacity of power system .

  26. 并联电抗器可以补偿容性充电功率,抑制工频过电压,并可减小单相重合闸时线路的潜供电容电流,是超高压电力系统的重要电气设备。

    A shunt reactor , which can compensate charging power , restrain the power frequency overvoltage , and decrease secondary arc capacitance current during single-phase reclosing in lines , is an important electrical equipment in Ultra High Voltage ( UHV ) power system .

  27. 电力系统是动态的,轻载运行情况下,线路的电压偏高,重载负荷运行情况下,电压偏低,如果用可控电抗器代替固定电抗器,则能兼顾工频过电压限制和无功功率的调节。

    Power system is dynamic , light load operation conditions , the line voltage on the high side , heavy load operation conditions , low voltage controlled reactor , if use , can replace fixed reactor both industrial frequency overvoltage restrictions and reactive power regulation .

  28. 算法模块包括初始路径的形成、自励磁计算、工频过电压计算、操作过电压计算、稳定性计算等功能,可以实现对所有路径方案的校核计算、方案可行性的判别以及路径有效性的排序等。

    Algorithm module includes the formation of initial path , self-excitation calculation , calculation of normal frequency overvoltage , operation overvoltage calculations and stability calculations and checking calculation of all paths , the feasibility judgment of the scheme , and ordering the paths according to their effectiveness .

  29. 特高压磁阀可控电抗器抑制工频暂态过电压的研究

    Measures to Suppress Transient Overvoltage at Working Frequency Using UHV Magnetically Controlled Reactor

  30. 故可得出结论:在中性点绝缘系统中,因电磁式电压互感器饱和引起的过电压现象属于工频位移过电压。

    Therefore , the over-voltage caused by the electromagnetic voltage transformer saturation in the system with insulated neutral belongs to shifting over-voltage .