拒动
- 【电力】failure to operate
-
TV二次回路多点接地造成保护拒动的实例分析
Instance Analysis fo the Miss Operation of the Protection Device Caused By Multiple Earth in the TV Secondary Circuit
-
SN(10)-10Ⅲ型断路器拒动分闸的原因及改进
Cause of SN_ ( 10 ) - 10 ⅲ Circuit Breakers Refusing Opening and It 's Modification
-
国内某电厂的定子接地保护拒动起因于不正确的PT接线。
Failure to operation of stator winding grounding fault occurred in a domestic power plant resulted from false PT secondary connection .
-
PV的接入会改变配电网的网络结构和潮流分布,导致保护可能出现拒动或误动等情况。
PV will change network structure and power flow distribution . This may easily result in tripping missing or mal operation of traditional protection .
-
关于RCD的误动作和拒动
False Action and Non-action about RCD
-
110kV变电所备自投供电线路拒动的原因分析
Analysis on the rejecting cause of 110 kV substation spare power supply line
-
昭东电站110kV主变后备保护拒动原因分析
Analysis of a maloperation of transformer 's backup protection in 110 kV Zhaodong station
-
330kV安南双回线主保护拒动问题分析
The Analysis for the Inactivity of 330 kV An-Nan Double-circuit Line
-
哈三电厂600MW发电机100%定子接地保护拒动分析
Analysis on Operation Rejection of 100 % Stator Ground Protection for 600 MW Generator of Harbin No.3 Power Plant
-
当馈线远方终端(FTU)拒动或通讯中断时,变电站馈出线的保护可作为远后备。
When feeder terminal unit ( FTU ) fails to act or communicate is interrupted , the feeder protection in the substation can backup .
-
一台550kV断路器拒动的分析与处理
Analysis and Treatment of Resist-operation on a 550 kV Circuit Breaker
-
仿真结果表明:FCL的投入会使线路零序电流保护灵敏性降低甚至产生拒动。
Simulation results show that , the insert of FCL will reduce the sensitivity of zero-sequence current protection even make the protection fail to operate .
-
按K(Zzd-Xc)整定保护范围时,故障分量距离元件可用于快速切除近端故障,对于远区故障,拒动、误动均有可能。
The fault component distance relay can be used to trip close fault rapidly when its protection range is set with K ( Zzd-Xc ) . however . In the case of remote fault .
-
指出分布电容在短路暂态过程中引起的振荡高频分量,可以导致快速母差保护拒动,其影响在保护设计时应引起重视。RCS-915型母差保护装置的保护方案考虑了线路分布电容的影响。
The high frequency component caused by distributed capacitance in transient process , may result in maloperation of busbar differential protections , which should be taken seriously in designing of RCS-915 differential protection .
-
某220kV线路故障,线路保护正确动作,但开关拒动,引起失灵保护动作、母线保护误动,最后造成两个220kV变电站全站失去电压。
During a fault occurred in a 220 kV line , the line protections acted correctly , but the breaker miss tripped . It caused breaker failure protection acted and bus protection maloperation , and the voltage of two 220 kV substation all lost .
-
断路器拒动后应采取的措施及其改进建议
Measures have to take after CB refused to switch and Improve-advice
-
3~SO2风机电控部分拒动故障分析
Analysis on trouble of electrical control drive for No.3 so_2 fan
-
开关拒动对于系统的危害是巨大的,同样对保护二次回路的危害也是不容小视的。
Switch 's failure does harm to system and the secondary circuit .
-
旁路母线微机保护重合闸拒动原因分析一例
Analysis of Miss Operation of Microcomputer Reclosing on By-pass Bus
-
11型线路微机零序保护拒动分析
Refusal-to-move Analysis for Zero Sequence Protection of Model 11 Microcomputer
-
本文详细地分析了该保护装置在发电机定子接地故障中拒动的原因。
This paper analyses detailedly the cause of operation rejection of protective device .
-
防止锅炉汽包水位保护拒动和误动的措施
Prevent Method of Boiler Drum Water Level Guard Operation no and Operation Error
-
解决变电站遥控拒动试验分析
Tests and analysis for resolving telecontrol failures in substations
-
一起安稳装置拒动原因分析及反事故措施
The reason analysis on missing operation of safety stability device and anti-accident measures
-
此外,该专家系统还可分析断路器和继电器的误动和拒动情况。
Also , the expert system can identify the misinformation from relays or breakers .
-
一起线路故障纵联方向保护拒动的分析及改进方案
Analysis and improving schemes of direction pilot protection rejecting movement in a line fault
-
接地故障零序方向元件拒动保护改进方案
Improvement on Zero Sequence Current Protection When Directional Element Fails to Operate During Earth Faults
-
单相接地保护装置拒动和误动的原因分析
Causation and Analysis of the Refuse and by Accident to Singe-phase Protection Equipment for Earthing
-
故障分量正序方向元件消除拒动措施分析
Analysis of Measures to Eliminate Trip Rejection of Positive Directional Relays Based on Fault Components
-
达系统设定保护动作值,而保护拒动时。
Protective devices are immovable when the protection value set by the system is reached ;