防火间距
- 网络fire separation distance
-
建筑物内部防火间距设计方法与案例研究
Study on Interior Fire Separation Distance Design Approach and Case Validation
-
对于大型浮顶油罐的防火间距,在介绍国外标准和做法的基础上,从安全、经济以及实践经验等方面论证了大型浮顶油罐20m防火间距的可行性。
The feasibility demonstration on 20 m spacing for large-scale floating roof oil tank is made from safety , economy and experiences .
-
石油(可燃液体)储罐区的防火间距
Distance of Fireproof in Oil ( Flammable Liquid ) Storage Area
-
大型浮顶油罐防火间距的可行性论证
Feasibility Demonstration on Spacing of Large-scale Floating Roof Oil Tank
-
关于干式煤气柜与湿式煤气柜防火间距问题的探讨
Discussion on the Fire Separation of Dry Gas Tank and Humid Gas Tank
-
某石油化工企业高架火炬防火间距的确定
Discussion on the determination of the fire separation of high-rack flare in a petro-chemical enterprise
-
真空辅助式油气回收系统对加油站防火间距的改善
Improvement of the Fireproofing Distance of Gasoline Station in Auxiliary Vacuum Oil - gas Recycling System
-
以设计实例为依据,确定管架防火间距;阐明厂外管架总图设计的原则。
Based on design practices , define space of fire proof pipe rack , and elaborate design principle of pipe rack of outside plant .
-
防火间距是建筑防火设计审核的基本控制参数,也是进行防火检查的重点问题。
Fire Protection Distance is a basic controls parameter to auditing fire protection design of building , and an important factor to prevent fire .
-
在石油化工厂总图设计中,不仅要考虑满足工艺流程和防火间距,还要对工厂的建筑空间和环境设计给予充分的重视。
In the design of a plot plan for a chemical plant , it is necessary to meet the requirements like process , fire protection distance as well as environmental protection .
-
(六)违反消防安全规定,占用防火间距,或者搭棚、盖房、挖沟、砌墙堵塞消防车通道的;
Occupying fire prevention belts , putting up shelters , building houses , digging trenches or building walls blocking the passage of fire engines in violation of the safety measures against fire ;
-
摘要文章对川东村镇住宅的合理间距做了初步的探讨,从日照标准、防火间距、相邻关系方面分析了规划区内外的住宅间距的大小,并给出了参考数值。
The reasonable house space between of villages and small towns in the east of Sichuan is explored from such aspects as sunlight , fire control and neighbourhood , which can be used as references .
-
某厂要增设第二套分子筛脱蜡装置,该项目存在场地小、拆迁工程量大、防火间距无法符合规范要求等老厂技术改造普遍存在的制约因素。
The second molecular sieve dewaxing unit is to be built in a refinery and there are a lot of restraint factors such as small area , a large amount of dismantlement and moving work , meanwhile the fireproofing distance is difficult to meet the specification .
-
以小型液化石油气站总图设计为例,对照国内外有关规范,提出其总图布置应放宽防火间距要求,以达到减少站区占地和降低工程造价之目的。
Take the design of small LPG station as an example , compared with the relevant design codes of China and of foreign countries , the author proposes that the fire distance limitation in the plot plan should be adjusted to reduce the land occupation and engineering cost .
-
针对正在运行的湿式煤气柜防火间距不够的位置动火建造大10倍的湿式煤气柜的实际情况,采取现场调查、安全系统分析,制订切实可行的措施,顺利完成施工任务。
In view of the situation that building a wet gas cabinet outnumbering the carrying wet gas cabinet ten to one at the insufficient fire distance place , taking the spot investigation and safety system analysis to formulate the feasible plan , and the construction task is completed smoothly .