防火间距

  • 网络fire separation distance
防火间距防火间距
  1. 建筑物内部防火间距设计方法与案例研究

    Study on Interior Fire Separation Distance Design Approach and Case Validation

  2. 对于大型浮顶油罐的防火间距,在介绍国外标准和做法的基础上,从安全、经济以及实践经验等方面论证了大型浮顶油罐20m防火间距的可行性。

    The feasibility demonstration on 20 m spacing for large-scale floating roof oil tank is made from safety , economy and experiences .

  3. 石油(可燃液体)储罐区的防火间距

    Distance of Fireproof in Oil ( Flammable Liquid ) Storage Area

  4. 大型浮顶油罐防火间距的可行性论证

    Feasibility Demonstration on Spacing of Large-scale Floating Roof Oil Tank

  5. 关于干式煤气柜与湿式煤气柜防火间距问题的探讨

    Discussion on the Fire Separation of Dry Gas Tank and Humid Gas Tank

  6. 某石油化工企业高架火炬防火间距的确定

    Discussion on the determination of the fire separation of high-rack flare in a petro-chemical enterprise

  7. 真空辅助式油气回收系统对加油站防火间距的改善

    Improvement of the Fireproofing Distance of Gasoline Station in Auxiliary Vacuum Oil - gas Recycling System

  8. 以设计实例为依据,确定管架防火间距;阐明厂外管架总图设计的原则。

    Based on design practices , define space of fire proof pipe rack , and elaborate design principle of pipe rack of outside plant .

  9. 防火间距是建筑防火设计审核的基本控制参数,也是进行防火检查的重点问题。

    Fire Protection Distance is a basic controls parameter to auditing fire protection design of building , and an important factor to prevent fire .

  10. 在石油化工厂总图设计中,不仅要考虑满足工艺流程和防火间距,还要对工厂的建筑空间和环境设计给予充分的重视。

    In the design of a plot plan for a chemical plant , it is necessary to meet the requirements like process , fire protection distance as well as environmental protection .

  11. (六)违反消防安全规定,占用防火间距,或者搭棚、盖房、挖沟、砌墙堵塞消防车通道的;

    Occupying fire prevention belts , putting up shelters , building houses , digging trenches or building walls blocking the passage of fire engines in violation of the safety measures against fire ;

  12. 摘要文章对川东村镇住宅的合理间距做了初步的探讨,从日照标准、防火间距、相邻关系方面分析了规划区内外的住宅间距的大小,并给出了参考数值。

    The reasonable house space between of villages and small towns in the east of Sichuan is explored from such aspects as sunlight , fire control and neighbourhood , which can be used as references .

  13. 某厂要增设第二套分子筛脱蜡装置,该项目存在场地小、拆迁工程量大、防火间距无法符合规范要求等老厂技术改造普遍存在的制约因素。

    The second molecular sieve dewaxing unit is to be built in a refinery and there are a lot of restraint factors such as small area , a large amount of dismantlement and moving work , meanwhile the fireproofing distance is difficult to meet the specification .

  14. 以小型液化石油气站总图设计为例,对照国内外有关规范,提出其总图布置应放宽防火间距要求,以达到减少站区占地和降低工程造价之目的。

    Take the design of small LPG station as an example , compared with the relevant design codes of China and of foreign countries , the author proposes that the fire distance limitation in the plot plan should be adjusted to reduce the land occupation and engineering cost .

  15. 针对正在运行的湿式煤气柜防火间距不够的位置动火建造大10倍的湿式煤气柜的实际情况,采取现场调查、安全系统分析,制订切实可行的措施,顺利完成施工任务。

    In view of the situation that building a wet gas cabinet outnumbering the carrying wet gas cabinet ten to one at the insufficient fire distance place , taking the spot investigation and safety system analysis to formulate the feasible plan , and the construction task is completed smoothly .